The HTTP IoT Push Data Advanced sensor displays data from messages that are received from Internet of Things (IoT) capable devices (for example, Sigfox devices) and that are pushed via an HTTPS request to PRTG. It provides a URL that you can use to push messages to the probe system via HTTPS (secured with TLS 1.2).
This sensor is especially useful when you want to push data to a PRTG Hosted Monitor instance.
HTTP IoT Push Data Advanced Sensor
For more information about the sensor usage, see section How to Use.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
Sensor in Other Languages
- Dutch: HTTP IoT Push Data Geavanceerd
- French: Données IoT avancé (HTTP Push)
- German: HTTP IoT Push-Daten (Erweitert)
- Japanese: HTTP IoT プッシュデータ(アドバンスト)
- Portuguese: Dados de push IoT (avançado) (HTTP)
- Russian: Дополнительные данные push-объекта HTTP IoT
- Simplified Chinese: HTTP IoT 高级推送数据
- Spanish: Datos push IoT (avanzado) (HTTP)
Remarks
Add Sensor
The Add Sensor dialog appears when you manually add a new sensor to a device. It only shows the settings that are required to create the sensor. You can change nearly all settings on the sensor's Settings tab after creation.
Basic Sensor Settings
Click the Settings tab of a sensor to change its settings.
Basic Sensor Settings
|
|
Sensor Name
|
Enter a name to identify the sensor.
|
Parent Tags
|
Shows tags that the sensor inherits from its parent device, parent group, and parent probe.
This setting is for your information only. You cannot change it.
|
Tags
|
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
It is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).
For performance reasons, it can take some minutes until you can filter for new tags that you added.
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- pushsensor
- pushdata
- httppushsensor
- iot
- sigfox
|
Priority
|
Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority () to the highest priority ().
|
Usually, a sensor connects to the IP Address/DNS Name of the parent device. See the device settings for details. For some sensors, you can explicitly define the monitoring target in the sensor settings.
TLS Settings
TLS Settings
|
|
TLS Version
|
The security of the incoming HTTPS push requests:
- HTTPS (secured with TLS 1.2 only): Send push messages to the probe system via HTTPS. The sensor only supports connections that are secured with TLS 1.2. It uses the SSL certificate that is delivered with PRTG or your own trusted SSL certificate that you imported for the PRTG web server.
If you install the sensor on a remote probe, make sure that you import the same SSL certificates to the remote probe as you use on the PRTG core server.
PRTG shows this setting for your information only. You cannot change it.
|
TLS Port
|
The number of the port on which this sensor listens for incoming HTTPS requests. This is always 5051.
PRTG shows this setting for your information only. You cannot change it.
|
HTTP Push Authentication
HTTP Push Authentication
|
|
Identification Token
|
This is the token that PRTG uses to find the matching sensor for the incoming message. When you create the sensor, this token is {__guid__}.
PRTG replaces this token with an automatically generated token after sensor creation. If you want to use a different identification token, you can edit it during or after sensor creation.
PRTG does not automatically replace the token if you change it already during sensor creation.
|
HTTP Push Data
HTTP Push Data
|
|
No Incoming Data
|
Define which status the sensor shows if it does not receive a push message for at least two scanning intervals:
- Ignore and keep last status (default): Keep the status as defined by the last message that the sensor received.
The parent probe must be connected to keep the last status. If the parent probe disconnects, the sensor shows the Unknown status. If the parent probe connects again, the sensor does not automatically switch from the Unknown status to the last status before the parent probe disconnected.
- Switch to unknown status: Show the Unknown status if the sensor does not receive a message for at least two scanning intervals.
- Switch to down status after x minutes: Show the Down status if the sensor does not receive a message within a specific time span. Define the time threshold below.
|
Time Threshold (Minutes)
|
This setting is only visible if you select Switch to down status after x minutes above. Enter a time threshold in minutes. If this time elapses, the sensor shows the Down status if it does not receive a push message within this time span.
Enter an integer. The maximum threshold is 1440 minutes.
|
Sensor Display
Sensor Display
|
|
Primary Channel
|
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab.
|
Graph Type
|
Define how different channels are shown for this sensor:
- Show channels independently (default): Show a graph for each channel.
- Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
You cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).
|
Stack Unit
|
This setting is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.
|
Inherited Settings
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Scanning Interval
Scanning Interval
For more information, see section Root Group Settings, section Scanning Interval.
Schedules, Dependencies, and Maintenance Window
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.
Schedules, Dependencies, and Maintenance Window
For more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.
Access Rights
Access Rights
For more information, see section Root Group Settings, section Access Rights.
How to Use
This function is known as a webhook. Basically, a webhook works like a push notification. Webhooks are usually triggered by an event (for example, a new comment on a blog post) and send according information to a specified URL. The HTTP IoT Push Data Advanced sensor then displays the data of pushed and received messages.
The data that is pushed to this sensor must be valid XML or JSON.
For details about the return value format, see section Custom Sensors.
The HTTP IoT Push Data Advanced sensor uses the following URLs depending on the type of HTTPS request.
- GET requests: https://<probe_ip>:5051/<token>?content=<valid XML_or_JSON>
The XML-encoded value of the content parameter has to match the format defined in section Custom Sensors.
- POST requests: https://<probe_ip>:5051/<token>
This HTTPS request method sends the XML-encoded or JSON-encoded HTTPS body as POST data. The body has to match the format defined in section Custom Sensors. We strongly recommend the HTTPS content type application/xml or application/json.
Replace the parameters <probe_ip>, <token>, and <valid XML_or_JSON> (for GET requests) with the corresponding values:
- For PRTG Network Monitor, the probe IP is the IP address of the probe system. For PRTG Hosted Monitor instances, the probe IP is the Domain Name System (DNS) name of the instance.
- The port number is always 5051. You cannot change this.
- You can define identification token in the sensor settings.
- The content of GET requests has to be valid XML or JSON in the PRTG API format.
The content has to be URL encoded (for example, the whitespaces in the sample URL below). Most browsers do the URL-encoding automatically.
Minimum example for the GET method that returns one static channel value:
https://127.0.0.1:5051/XYZ123?content=<prtg><result><channel>MyChannel</channel><value>10</value></result><text>this%20is%20a%20message</text></prtg>
By default, values within the <value> tags in the returned XML or JSON must be integers for them to be processed. If float values are returned, you must explicitly define this value type as defined in section Custom Sensors with <float> tags, otherwise the sensor shows 0 values in affected channels. Example:
https://127.0.0.1:5051/XYZ123?content=<prtg><result><channel>MyChannel</channel><value>10.45</value><float>1</float></result><text>this%20is%20a%20message</text></prtg>
You can use several sensors with the same port and identification token. In this case, push message data is shown in each of these sensors.
Channel List
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
|
|
Downtime
|
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status in percent.
|
[Value]
|
The data received from the message encoded in valid Extensible Markup Language (XML) or JavaScript Object Notation (JSON) in several channels
This channel is the primary channel by default.