<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: SNMP Dell PowerEdge Physical Disk Sensor
The SNMP Dell PowerEdge Physical Disk sensor monitors a physical disk in a Dell PowerEdge server via the Simple Network Management Protocol (SNMP).
SNMP Dell PowerEdge Physical Disk Sensor
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
Sensor in Other Languages
- Dutch: SNMP-Dell PowerEdge Fysieke Schijf
- French: Dell PowerEdge disque physique (SNMP)
- German: SNMP Dell PowerEdge Physikalischer Datenträger
- Japanese: SNMP Dell PowerEdge 物理ディスク
- Portuguese: Disco físico Dell PowerEdge (SNMP)
- Russian: Физический диск Dell PowerEdge по SNMP
- Simplified Chinese: SNMP Dell PowerEdge 物理磁盘
- Spanish: Disco físico Dell PowerEdge (SNMP)
Remarks
Detailed Requirements
|
|
Dell OpenManage Server Administrator or iDRAC 7
|
This sensor needs the Dell OpenManage Server Administrator (OMSA) tool to be installed on the target device to monitor it. Make sure that you enable SNMP in the OMSA.
For details, see the Knowledge Base: What do I need to monitor Dell servers?
You can also monitor Dell PowerEdge servers with this sensor via iDRAC 7.
|
Add Sensor
The Add Sensor dialog appears when you manually add a new sensor to a device. It only shows the settings that are required to create the sensor. You can change nearly all settings on the sensor's Settings tab after creation.
The settings that you select in the Add Sensor dialog are valid for all sensors that you create when you finish the dialog.
Dell PowerEdge Physical Disk Settings
|
|
Disk
|
Select the physical disks that you want to monitor. PRTG creates one sensor for each physical disk that you select.
Enable check boxes in front of the respective lines to select the items. Use the check box in the table header to select all items or to cancel the selection. In large tables, use the search function in the upper-right corner.
|
Basic Sensor Settings
Click the Settings tab of a sensor to change its settings.
Basic Sensor Settings
|
|
Sensor Name
|
Enter a name to identify the sensor.
|
Parent Tags
|
Shows tags that the sensor inherits from its parent device, parent group, and parent probe.
This setting is for your information only. You cannot change it.
|
Tags
|
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
It is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).
For performance reasons, it can take some minutes until you can filter for new tags that you added.
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- snmpdellphysicaldisksensor
- physicaldisk
- snmpdell
- dell
|
Priority
|
Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority () to the highest priority ().
|
Usually, a sensor connects to the IP Address/DNS Name of the parent device. See the device settings for details. For some sensors, you can explicitly define the monitoring target in the sensor settings.
Dell PowerEdge Physical Disk Settings
Dell PowerEdge Physical Disk Settings
|
|
Disk
|
Shows the physical disk that this sensor monitors.
PRTG shows this value for reference purposes only. If you need to change this value, add the sensor anew.
|
Data Source
|
Shows the interface that PRTG uses to get monitoring data. This is either Dell OMSA or iDRAC.
PRTG shows this value for reference purposes only. If you need to change this value, add the sensor anew.
|
Sensor Display
Sensor Display
|
|
Primary Channel
|
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab.
|
Graph Type
|
Define how different channels are shown for this sensor:
- Show channels independently (default): Show a graph for each channel.
- Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
You cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).
|
Stack Unit
|
This setting is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.
|
Inherited Settings
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Scanning Interval
Scanning Interval
For more information, see section Root Group Settings, section Scanning Interval.
Schedules, Dependencies, and Maintenance Window
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.
Schedules, Dependencies, and Maintenance Window
For more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.
Access Rights
Access Rights
For more information, see section Root Group Settings, section Access Rights.
Channel Unit Configuration
Which channel units are available depends on the sensor type and the available parameters. If no configurable channels are available, this field shows No configurable channels.
Channel Unit Configuration
For more information, see section Root Group Settings, section Channel Unit Configuration.
Channel List
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
|
|
Component Status
|
The component status
- Up status: Ok
- Warning status: Non Critical
- Down status: Critical, Non Recoverable, Other, Unknown
|
Disk State
|
The disk state
- Up status: Non-Raid, Online, Ready
- Warning status: Foreign
- Down status: Blocked, Critical, Failed, Non Recoverable, Other, Removed, Unknown
This channel is the primary channel by default.
|
Downtime
|
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status in percent.
|
Roll Up Status
|
The roll up status
- Up status: Ok
- Warning status: Non Critical
- Down status: Critical, Non Recoverable, Other, Unknown
|
S.M.A.R.T. Warning
|
The Self-Monitoring, Analysis and Reporting Technology (S.M.A.R.T.) status warning
- Up status: No
- Down status: Yes
|
More
Knowledge Base
What do I need to monitor Dell servers?
I can't add Dell PowerEdge sensors to PRTG. What can I do?
My Dell PowerEdge sensor fails to validate disks and I can't add it. What can I do?
What security features does PRTG include?
My SNMP sensors don’t work. What can I do?